End-to-end fan services from survey to commissioning
With our experienced service engineers we handle the entire process, including site survey, installation, repair and maintenance.
-
Site Survey & Consultation
We inspect site conditions, assess existing equipment and recommend the best course of action.
-
Energy Audit
We measure motor power, airflow and pressure to determine fan efficiency and prepare a savings and payback report.
-
Cooling Tower Retrofit
We increase efficiency and capacity in existing towers by renewing fan wheels, fan stacks and FRP components.
-
Installation & Commissioning
Delivery, installation, blade-angle setting and start-up carried out by trained teams.
-
Static & Dynamic Balancing
We balance impellers on site to the lowest tolerances, reducing vibration and mechanical wear.
-
Inspection & Performance Testing
We verify performance with before-and-after measurements and report the results.
-
Technical Support & Breakdown
Emergency breakdown response, in-situ repairs and rebuilding to minimise downtime.
-
Spare Parts
Supply and change-out of genuine spare blades, hubs, bushes and fasteners.
Three steps we follow on every project
We don’t recommend before measuring, and we don’t hand over before verifying.
- 1
Step 1: Survey & Measurement
We record the current state on site with airflow, pressure, motor power and vibration measurements.
- 2
Step 2: Engineering & Selection
We select blade count, angle and diameter for your process and report savings and payback time.
- 3
Step 3: Installation & Verification
After installation, balancing and commissioning, we run a performance test and document the results.
Frequently asked questions about energy-efficient fans
What is an FRP fan and how does it differ from a metal fan?
FRP (fibre-reinforced polymer) fan blades are moulded to follow the aerodynamic profile exactly; they are light and corrosion resistant. They run at higher efficiency than metal blades, draw 15–35% less power for the same airflow and reduce the load on gearboxes and bearings.
Can I replace only the fan in my existing cooling tower?
Yes. In most retrofit projects the motor and gearbox are kept and only the fan wheel (hub + blades) is replaced. If needed, the fan stack and inlet are also improved for extra efficiency.
How are the energy savings verified?
Motor power, airflow and vibration are measured at the same points before and after the change. Results are reported in line with CTI ATC-143 and AMCA 210 approaches.
Which fan diameters and airflows are possible?
Axial fans are available in diameters from 600 mm to 12,000 mm with 4–16 blades and airflows up to 3,000,000 CFM (1,420 m³/s) per fan.
Who handles delivery and installation in Türkiye?
Import, customs, delivery to site, installation, balancing and commissioning are coordinated by Saruhan Ventures from our Istanbul head office and Düzce branch.
What is the payback period?
Savings depend on the number of fans, operating hours and electricity price. In plants running 24/7 the payback period is usually short. You can make a preliminary estimate with the calculator on our site and request a free survey for an exact report.
Start reducing your fan energy today
Send us your existing fan data and we will calculate your savings potential free of charge.
- Lower energy bills
- Reduced carbon emissions
- Less vibration and maintenance
- Local engineering support