Technology
Efficiency is no accident: a chain of profile, material, manufacturing and testing.
-
Aerofoil Blade Profile
Profile conforming to NACA 23012 with a high lift-to-drag ratio; optimised twist, taper and camber for uniform flow along the blade.
-
Vacuum Infusion Moulding
Consistent fibre-to-resin ratio, uniform wall thickness and high strength with VIP in closed moulds; a separate mould for each blade size.
-
Balancing & Moment Matching
Every blade is dynamically balanced and moment-matched; impellers are balanced to ISO 1940 grade G6.3 / G2.5.
-
R&D & Collaboration
Joint R&D projects with institutions such as TIFAC’s Advanced Composites Mission, ATIRA and DSIR.
-
Testing Facilities
Laboratory fan tests to AMCA 210, field tests on cooling towers to CTI ATC-143, surface resistivity to ASTM D257.
-
Design & Engineering
Impellers and hubs are designed and tested for worst-case aerodynamic and centrifugal load scenarios.
FRP aerofoil fan technology in numbers
Total efficiency of conventional metal fans often stays in the 55–65% range. Well-designed FRP aerofoil blades move more air with the same motor.
Codes & Standards
Fan design, composite materials, metal components and test procedures are based on recognised standards.
Fan design & manufacturing
- API 661
- ASTM D4167
- IS 10470
- IS 2825
Composite material
- IS 11320
- IS 11551
- IS 6746
Metallic hub components
- BS 1490
- IS 617
- IS 210
- IS 2062
- IS 2629
- IS 2633
- AISI 304
Testing
- ISO 1940
- ASTM D257
- AMCA 210
- CTI ATC-143
Start reducing your fan energy today